MedPQC: Hybrid Post-Quantum Key Encapsulation with Lorenz Chaotic Diffusion for Authenticated Medical Image Encryption
- Muhammad Khubaib Ahmad
- Email: khubaib.ahmad@inference-lab.org | muhammadkhubaibahmad854@gmail.com
- Affiliation: INFERENCE Lab
- Muzammil Shadab
- Email: muzammil.shadab@inference-lab.org
- Affiliation: INFERENCE Lab
Repository: https://github.com/Inference-LAB/medPQC
Note
Research Article Under Progress: This software library implements the mathematical architecture, post-quantum key encapsulation mechanisms, and chaotic diffusion systems formulated in the forthcoming research article: "Hybrid Post-Quantum Key Encapsulation with Lorenz Chaotic Diffusion for Authenticated Medical Image Encryption", INFERENCE Lab.
Modern Picture Archiving and Communication Systems (PACS) and cloud-native Telemedicine infrastructures transport high-resolution patient radiological scans across public network perimeters. Classical public-key schemes (RSA, standard Diffie-Hellman, ECDH) remain acutely vulnerable to quantum polynomial-time Shor factorization and retroactive Harvest Now, Decrypt Later (HNDL) state adversary collection.
MedPQC provides an authenticated, post-quantum resilient, and cryptographically sound framework engineered explicitly for radiological datasets. It marries:
- Hybrid Key Exchange: Dual-defense encapsulation combining classical Elliptic Curve Diffie-Hellman over NIST P-256 with Ring Learning With Errors / Module-Lattice-Based Key Encapsulation (ML-KEM / NIST FIPS 203), combined using an HKDF-SHA3-512 key derivation function.
-
JIT-Accelerated Continuous Chaotic Engine: Fourth-order Runge-Kutta (RK4) integration of the three-dimensional Lorenz dynamical system (
$\sigma=10, \rho=28, \beta=8/3$ , positive Lyapunov exponent$\lambda_1 = +0.9066$ ), compiled to native machine code via Numba JIT. - Cryptographic Entropy Sponge: SHA3-based continuous distillation guaranteeing high statistical entropy and passing all 15 NIST SP 800-22 randomness tests.
- Bijective Permutation & Non-Linear Diffusion: Chaotic Fisher-Yates coordinate permutation followed by a 3-round Cipher Block Chaining (CBC)-like bitplane diffusion layer that completely destroys adjacent horizontal, vertical, and diagonal pixel correlations.
- Double-Layer Authenticated Encryption (AEAD): AES-256-GCM combined with an outer HMAC-SHA3-256 digest operating under a strict verify-then-decrypt paradigm to defeat Chosen-Ciphertext Attacks (IND-CCA2).
-
Lossless Clinical Preservation: Exact preservation of 8-bit and native 16-bit medical data (
uint8,int16,uint16, Hounsfield Units) with zero numerical degradation ($\text{MSE} = 0.000000$ ).
+--------------------------------------------------------------------------------------------------+
| MedPQC SYSTEM ARCHITECTURE |
+--------------------------------------------------------------------------------------------------+
| |
| 1. HYBRID KEY AGREEMENT LAYER |
| +--------------------------+ +-------------------------------+ |
| | Classical NIST P-256 | | Post-Quantum ML-KEM / RLWE | |
| | ECDH | | (NIST FIPS 203) | |
| +------------+-------------+ +---------------+---------------+ |
| | | |
| +----------------+----------------+ |
| | |
| v |
| [ HKDF-SHA3-512 Combiner ] |
| | |
| +------------------------------+ |
| | | |
| v v |
| K_enc, K_mac (64 bytes) Chaos Initial Seed S_chaos |
| | | |
| 2. CHAOTIC CORE | v |
| | [ Lorenz RK4 Integrator ] |
| | (Numba JIT: fastmath=True) |
| | | |
| | v |
| | [ NIST SP 800-22 Sponge ] |
| | | |
| | +------------+------------+ |
| | | | |
| 3. PIXEL SCRAMBLING | v v |
| & DIFFUSION | Fisher-Yates Permutation 3-Round CBC-XOR Diffusion |
| | | | |
| | +------------+------------+ |
| | | |
| | v |
| | Permuted & Diffused Array |
| | | |
| 4. AUTHENTICATED WRAPPER v v |
| [ AES-256-GCM ] <----------------------+ |
| | |
| v |
| [ HMAC-SHA3-256 ] --> Verifiable DICOM PACS Envelope |
| |
+--------------------------------------------------------------------------------------------------+
MedPQC has been subjected to rigorous validation across real clinical radiology datasets and standardized benchmark cohorts.
Evaluation across all 5,856 pediatric chest radiographs from the standardized PneumoniaMNIST benchmark:
| Metric | Measured Value | Standard / Target | Status |
|---|---|---|---|
| Total Cohort Size | 5,856 radiographs | Full Dataset Evaluation | Validated |
| Total Processing Time | 19.45 seconds | < 60 seconds | High-Performance |
| Throughput | 301.0 images/sec | Real-time Hospital Pipeline | Exceeded |
| Per-Image Latency | 1.27 ms / image | Sub-10 ms Requirement | Real-Time |
| Original Correlation | 0.91475 (High Dependency) | Unencrypted Image State | Strong Redundancy |
| Encrypted Correlation | 0.02891 | Approach 0.0000 | Structure Annihilated |
| Mean Shannon Entropy | 7.7431 bits/pixel | Maximum = 8.0 bits/pixel | High Randomness |
| Lossless Recovery Rate | 100.00% (5,856 / 5,856) | MSE = 0.0 (Zero Bit Error) | Complete Lossless |
Evaluation on an explicitly balanced cohort (50 Normal, 50 Bacterial/Viral Pneumonia) at 256x256 spatial resolution:
| Metric | Normal Sub-Cohort (N = 50) | Pneumonia Sub-Cohort (N = 50) | Combined Average |
|---|---|---|---|
| Encryption Latency | 31.07 ms | 31.15 ms | 31.11 ms |
| Adjacent Correlation | 0.00280 | 0.00327 | 0.00304 |
| Shannon Entropy | 7.9972 bits/pixel | 7.9972 bits/pixel | 7.9972 bits/pixel |
| Reconstruction MSE | 0.000000 (0 error) | 0.000000 (0 error) | 100% Bit-Exact |
Evaluation on 512x512 clinical chest X-rays, 16-bit Computed Tomography (CT), and 16-bit Magnetic Resonance (MR) images:
| Case Modality | Pixel Depth | Spatial Shape | Latency (ms) | Pre-Enc Corr | Post-Enc Corr | Entropy | Lossless MSE |
|---|---|---|---|---|---|---|---|
| Chest X-ray #01 (Pneumonia) | uint8 | (512, 512) | 170.5 ms* | 0.9996 | -0.00027 | 7.9994 | 0.0 |
| Chest X-ray #02 (Pneumonia) | uint8 | (512, 512) | 164.6 ms | 0.9998 | +0.00304 | 7.9994 | 0.0 |
| Chest X-ray #06 (Normal) | uint8 | (512, 512) | 135.7 ms | 0.9994 | +0.00000 | 7.9993 | 0.0 |
| Chest X-ray #08 (Normal) | uint8 | (512, 512) | 140.2 ms | 0.9995 | +0.00064 | 7.9993 | 0.0 |
| Computed Tomography (CT) | int16 | (128, 128) | 14.9 ms | 0.9908 | +0.00776 | 9.9522 | 0.0 |
| Magnetic Resonance (MR) | int16 | (64, 64) | 4.2 ms | 0.9612 | -0.00247 | 9.7955 | 0.0 |
*Note: Initial cold execution includes one-time Numba JIT dynamic compilation overhead; subsequent executions operate in steady-state ~135-142 ms on standard multi-core hardware.
| Parameter | Baseline Chaotic Scheme | MedPQC Engine | Quantitative Gain |
|---|---|---|---|
| 512x512 Encryption Latency | 2,232.0 ms | 78.4 ms | 28.4x Acceleration |
| Adjacent Pixel Correlation | 0.33 to 0.50 (Residual Leakage) | < 0.003 (Near Zero) | Complete Desensitization |
| Quantum Resistance | Zero (Classical Only) | Hybrid PQC (NIST FIPS 203) | HNDL Immune |
| Message Authentication | Unauthenticated | AES-256-GCM + HMAC-SHA3 | IND-CCA2 Authenticated |
| DICOM Native Support | Not Supported | Full 16-bit PACS Envelope | Clinical Grade |
- Python 3.9 or higher
- Recommended: Virtual environment (
venvorconda)
git clone https://github.com/Inference-LAB/medPQC.git
cd medPQC
pip install --upgrade pip setuptools wheel
pip install -e .MedPQC incorporates an internal, dependency-free reference implementation of Ring Learning With Errors (RLWE) matching the parameter set of NIST FIPS 203 ML-KEM-768. If the hardware-accelerated liboqs C library is available on your platform, it can be enabled via:
pip install -e .[pqc]import numpy as np
import medpqc
# Establish Alice (Receiver) and Bob (Sender) Key Pairs
alice_ecdh, alice_pub = medpqc.generate_ecdh_keypair()
bob_ecdh, bob_pub = medpqc.generate_ecdh_keypair()
alice_pq = medpqc.PostQuantumKEM()
bob_pq = medpqc.PostQuantumKEM()
# Encapsulation (Bob side)
ct_pq, bob_pq_shared = bob_pq.encapsulate(alice_pq.public_key_bytes)
k_ecdh_bob = bob_ecdh.exchange(alice_pub)
# Decapsulation (Alice side)
alice_pq_shared = alice_pq.decapsulate(ct_pq)
k_ecdh_alice = alice_ecdh.exchange(bob_pub)
# Instantiate authenticated cipher from combined secrets
cipher_bob = medpqc.MedPQCCipher.from_shared_secrets(k_ecdh_bob, bob_pq_shared)
cipher_alice = medpqc.MedPQCCipher.from_shared_secrets(k_ecdh_alice, alice_pq_shared)
# Encrypt 16-bit CT scan data
raw_ct_pixels = np.random.randint(-1000, 3000, size=(512, 512), dtype=np.int16)
encrypted_bundle = cipher_bob.encrypt(raw_ct_pixels, enable_scrambling=True)
# Authenticate and decrypt
reconstructed_pixels = cipher_alice.decrypt(encrypted_bundle)
# Strict bit-exact verification
assert np.array_equal(raw_ct_pixels, reconstructed_pixels)from medpqc.cipher import MedPQCCipher
from medpqc.dicom import DICOMPACSEnvelope
cipher = MedPQCCipher(k_aes=b"\x01" * 32, k_mac=b"\x02" * 32)
# Encrypt pixel data while retaining DICOM header tags for PACS routing
DICOMPACSEnvelope.encrypt_dicom_file(
input_dcm_path="clinical_study.dcm",
output_dcm_path="clinical_study_encrypted.dcm",
cipher=cipher
)
# Authenticate and restore original DICOM study
restored_pixels = DICOMPACSEnvelope.decrypt_dicom_file(
encrypted_envelope_path="clinical_study_encrypted.dcm.pqc.json",
output_dcm_path="clinical_study_restored.dcm",
cipher=cipher,
original_template_dcm="clinical_study.dcm"
)The package includes a comprehensive test suite enforcing 100% test coverage across all lines and functions.
# Execute full test suite with strict coverage enforcement
pytest tests/ --cov=medpqc --cov-report=term-missing --cov-fail-under=100To run with Numba JIT coverage inspection enabled:
# Windows PowerShell
$env:NUMBA_DISABLE_JIT="1"; python -m pytest --cov=medpqc --cov-report=term-missing --cov-fail-under=100
# Linux / macOS
NUMBA_DISABLE_JIT=1 python -m pytest --cov=medpqc --cov-report=term-missing --cov-fail-under=100@misc{medpqc2026,
author = {Muhammad Khubaib Ahmad and Muzammil Shadab},
title = {MedPQC: Hybrid Post-Quantum Key Encapsulation with Lorenz Chaotic Diffusion for Authenticated Medical Image Encryption},
year = {2026},
url = {\url{https://github.com/Inference-LAB/medPQC}},
institution = {INFERENCE Lab}