Original file line number Diff line number Diff line change
Expand Up @@ -174,13 +174,17 @@ namespace energyplus {

boost::optional<Node> inletNode(const PlantLoop& plantLoop, const HVACComponent& component) {
auto comps = plantLoop.supplyComponents(plantLoop.supplyInletNode(), component);
OS_ASSERT(comps.size() >= 2u);
if (comps.size() < 2u) {
return boost::none;
}
return (comps.end() - 2u)->optionalCast<Node>();
}

boost::optional<Node> outletNode(const PlantLoop& plantLoop, const HVACComponent& component) {
auto comps = plantLoop.supplyComponents(component, plantLoop.supplyOutletNode());
OS_ASSERT(comps.size() >= 2u);
if (comps.size() < 2u) {
return boost::none;
}
return comps[1].optionalCast<Node>();
}

Expand Down Expand Up @@ -437,7 +441,9 @@ namespace energyplus {
for (const auto& comp : subsetCastVector<HVACComponent>(plantLoop.supplyComponents())) {
if (!comp.optionalCast<Node>()) {
if (_isSetpointComponent(plantLoop, comp)) {
result.push_back(operationSchemeComponent(comp));
// Keep comp as-is (not operationSchemeComponent(comp)): inletNode/outletNode/flowrate
// below need the component that's actually on the supply branch.
result.push_back(comp);
}
}
}
Expand Down Expand Up @@ -543,16 +549,21 @@ namespace energyplus {
}

for (auto& setpointComponent : t_setpointComponents) {
// translationComponent may be a containing component (eg: HeatPumpAirToWater), used only
// for translation/naming below; setpointComponent stays the one on the supply branch for
// the inletNode/outletNode/flowrate/componentType lookups.
auto translationComponent = operationSchemeComponent(setpointComponent);

// TODO: @kbenne, Find the right way to deal with this
// For now, "dirty" (?) fix for Generator:MicroTurbine

boost::optional<IdfObject> _idfObject;

if (boost::optional<GeneratorMicroTurbineHeatRecovery> mchpHR = setpointComponent.optionalCast<GeneratorMicroTurbineHeatRecovery>()) {
if (boost::optional<GeneratorMicroTurbineHeatRecovery> mchpHR = translationComponent.optionalCast<GeneratorMicroTurbineHeatRecovery>()) {
GeneratorMicroTurbine mchp = mchpHR->generatorMicroTurbine();
_idfObject = translateAndMapModelObject(mchp);
} else {
_idfObject = translateAndMapModelObject(setpointComponent);
_idfObject = translateAndMapModelObject(translationComponent);
}

OS_ASSERT(_idfObject);
Expand Down
49 changes: 49 additions & 0 deletions src/energyplus/Test/PlantEquipmentOperationSchemes_GTest.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -40,6 +40,8 @@
#include "../../model/GroundHeatExchangerHorizontalTrench.hpp"
#include "../../model/GroundHeatExchangerVertical.hpp"
#include "../../model/HeatExchangerFluidToFluid.hpp"
#include "../../model/HeatPumpAirToWater.hpp"
#include "../../model/HeatPumpAirToWaterHeating.hpp"
#include "../../model/HeatPumpAirToWaterFuelFiredHeating.hpp"
#include "../../model/HeatPumpAirToWaterFuelFiredCooling.hpp"
#include "../../model/HeatPumpWaterToWaterEquationFitCooling.hpp"
Expand Down Expand Up @@ -522,6 +524,53 @@ TEST_F(EnergyPlusFixture, ForwardTranslator_PlantEquipmentOperationSchemes_Both_
EXPECT_EQ("Dual", w_eg.getString(PlantEquipmentOperation_ComponentSetpointExtensibleFields::OperationType).get());
}

TEST_F(EnergyPlusFixture, ForwardTranslator_PlantEquipmentOperationSchemes_HeatPumpAirToWaterHeating_ComponentSetpoint) {
// Test for #5665 - segfault when a SetpointManager is on the outlet node of a
// HeatPumpAirToWaterHeating, since it isn't itself on the plant loop (its containing
// HeatPumpAirToWater is translated/named instead, but node lookups need the actual component)

Model m;

HeatPumpAirToWater awhp(m);
HeatPumpAirToWaterHeating awhp_hc(m);
ASSERT_TRUE(awhp.setHeatingOperationMode(awhp_hc));

PlantLoop hwLoop(m);
ASSERT_TRUE(hwLoop.addSupplyBranchForComponent(awhp_hc));

ScheduleConstant sch(m);
SetpointManagerScheduled spm(m, sch);
ASSERT_TRUE(awhp_hc.outletModelObject());
Node outletNode = awhp_hc.outletModelObject()->cast<Node>();
ASSERT_TRUE(spm.addToNode(outletNode));

ForwardTranslator ft;
Workspace w = ft.translateModel(m);

boost::optional<WorkspaceObject> _wo = w.getObjectByTypeAndName(IddObjectType::PlantLoop, hwLoop.name().get());
ASSERT_TRUE(_wo.is_initialized());
WorkspaceObject idf_loop = _wo.get();
WorkspaceObject idf_plant_op = idf_loop.getTarget(PlantLoopFields::PlantEquipmentOperationSchemeName).get();

// HeatPumpAirToWaterHeating is Heating type, so it also lands on the default HeatingLoad scheme
// in addition to the ComponentSetpoint one created because of the SetpointManager
ASSERT_EQ(2u, idf_plant_op.extensibleGroups().size());
auto w_eg = idf_plant_op.extensibleGroups()[1].cast<WorkspaceExtensibleGroup>();
ASSERT_EQ("PlantEquipmentOperation:ComponentSetpoint",
w_eg.getString(PlantEquipmentOperationSchemesExtensibleFields::ControlSchemeObjectType).get());

_wo = w_eg.getTarget(PlantEquipmentOperationSchemesExtensibleFields::ControlSchemeName);
ASSERT_TRUE(_wo.is_initialized());
WorkspaceObject idf_op_scheme = _wo.get();

ASSERT_EQ(1u, idf_op_scheme.extensibleGroups().size());
w_eg = idf_op_scheme.extensibleGroups()[0].cast<WorkspaceExtensibleGroup>();
EXPECT_EQ("HeatPump:AirToWater", w_eg.getString(PlantEquipmentOperation_ComponentSetpointExtensibleFields::EquipmentObjectType).get());
EXPECT_EQ(awhp.nameString(), w_eg.getString(PlantEquipmentOperation_ComponentSetpointExtensibleFields::EquipmentName).get());
EXPECT_TRUE(w_eg.getString(PlantEquipmentOperation_ComponentSetpointExtensibleFields::DemandCalculationNodeName));
EXPECT_TRUE(w_eg.getString(PlantEquipmentOperation_ComponentSetpointExtensibleFields::SetpointNodeName));
}

TEST_F(EnergyPlusFixture, ForwardTranslator_PlantEquipmentOperationSchemes_HeatPumpPlantLoopEIR) {
Model m;

Expand Down