Repository navigation
fix(k8s): include MetalLB interfaces in Cilium devices - #1042
Open
hemanthnakkina wants to merge 1 commit into
Open
hemanthnakkina wants to merge 1 commit into
hemanthnakkina wants to merge 1 commit into
Conversation
gboutry
reviewed
Nov 25, 2026
Resolve each control node’s internal and public Juju space interfaces and include the storage interface when the optional MAAS MetalLB pool exists. Keep the internal interface as the direct-routing device when multiple devices are needed. During MAAS instance recovery enablement, reconcile Cilium and storage L2 advertisements before assigning the Consul storage VIP. Closes-Bug: #2175721 Assisted-By: codex-gpt-6.2sol
hemanthnakkina
force-pushed
the
fix/lp2175721-cilium-public-device
branch
from
November 25, 2026 14:47
165aac3 to
44826af
Compare
gboutry
approved these changes
Nov 25, 2026
hemanthnakkina
marked this pull request as ready for review
November 25, 2026 14:50
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Resolve each control node’s internal and public Juju space interfaces and include the storage interface when the optional MAAS MetalLB pool exists. Keep the internal interface as the direct-routing device when multiple devices are needed.
During MAAS instance recovery enablement, reconcile Cilium and storage L2 advertisements before assigning the Consul storage VIP.
Closes-Bug: #2175721
Assisted-By: codex-gpt-6.2sol
QA steps
Links
Jira card: OPEN-5005