Engine Cooling Controller

A small Embedded C project that simulates an engine cooling fan controller on a PC. It uses a finite-state machine, temperature hysteresis, sensor-fault handling, and a hardware abstraction interface to command fan outputs.

The project is automotive-inspired, but it is not firmware for a real ECU. It demonstrates control logic and host-based, software-in-the-loop-style testing without a microcontroller or physical fan.

Features

  • Three fan states: FAN_OFF, FAN_LOW, and FAN_HIGH
  • Configurable temperature thresholds, checked during initialization
  • Two-stage hysteresis to avoid frequent fan switching
  • Simulated PWM commands: 0%, 50%, and 100%
  • Hardware abstraction callbacks for fan PWM and a fault indicator
  • Detection of invalid sensor signals and out-of-range readings
  • HIGH fan fallback during sensor faults
  • Recovery after three consecutive valid readings
  • A simplified closed-loop thermal simulation and 10 automated C tests
  • GitHub Actions workflow for compilation, tests, and Cppcheck analysis

Architecture

Simulated thermal plant
         |
         v
Temperature + sensor validity
         |
         v
+------------------------------+
| Cooling controller (C)       |
| - configuration validation   |
| - state machine + hysteresis |
| - sensor fault / recovery    |
+------------------------------+
         |
         v
  HAL callbacks (mocked on PC)
         |
         +--> PWM command (0 / 50 / 100%)
         +--> Fault indicator (ON / OFF)
         |
         v
 Simulated cooling effect
         |
         +---- feedback to thermal plant

The controller is in src/cooling_controller.c. The PC simulation in src/main.c supplies temperatures and receives outputs through callback functions. This separation makes the control logic testable without hardware and allows a future target-specific driver to implement the same interface.

Fan states and hysteresis

Default configuration:

Transition Temperature PWM after transition
OFF → LOW 100°C or higher 50%
LOW → OFF 95°C or lower 0%
LOW → HIGH 110°C or higher 100%
HIGH → LOW 105°C or lower 50%

The controller can also move directly from OFF to HIGH at 110°C or above, or from HIGH to OFF at 95°C or below. Because of hysteresis, a temperature alone does not always determine the state: the previous state matters.

The defaults are for demonstration. They are not calibrated for a particular vehicle.

Configuration checks

cooling_init() rejects null arguments and threshold configurations that do not satisfy:

low_off_c < low_on_c < high_off_c < high_on_c

It also requires the lowest OFF threshold to be above -40°C and the highest ON threshold to be below 150°C. A valid configuration initializes the controller in FAN_OFF.

Sensor faults and recovery

A reading is considered invalid if sensor_valid is false or the measured temperature is outside -40°C to 150°C (inclusive).

On an invalid reading, the controller sets sensor_fault, resets its valid-reading counter, and commands FAN_HIGH (100% PWM). The fault indicator callback is set to ON when registered.

The fault clears only after three consecutive valid updates. At that point, the controller evaluates the normal hysteresis rules starting from HIGH:

Temperature at recovery Result
95°C or below OFF
Above 95°C through 105°C LOW
Above 105°C Remains HIGH

A new invalid reading during recovery restarts the counter. The HIGH fallback is an educational policy, not a validated functional-safety mechanism.

Closed-loop simulation

src/main.c runs a deterministic 20-step simulation. It changes a simplified heating rate, subtracts cooling based on the previous fan state, and feeds the resulting temperature back into the controller. It also injects a sensor signal fault and an out-of-range measurement.

The simulation prints the step, heating rate, measured temperature, sensor status, fan state, PWM command, and fault indicator. The thermal model is intentionally simple; it is not a physically calibrated engine model.

MATLAB-based validation (R2024a)

The C simulation can export a 20-step trace for independent checking and visualization in MATLAB. The C controller is unchanged; MATLAB serves as an offline reference model, not as an ECU runtime component.

  1. From Git Bash at the repository root, run make trace. This generates results/cooling_trace.csv (ignored by Git).

  2. In MATLAB, change to the repository folder and run:

    addpath('matlab')
    analyze_cooling

The MATLAB script reads the CSV, calculates a separate FSM/fault-recovery reference, checks every recorded state and output, and saves a four-panel figure to results/cooling_analysis.png. MATLAB R2024a is supported; no Simulink or other add-on is required for this workflow.

The reference model checks the supplied 20-step test scenario, not all possible input sequences. This is offline cross-checking, not real-time co-simulation, hardware-in-the-loop testing, or functional-safety evidence.

MATLAB validation results

The following plots show temperature evolution, injected sensor faults, PWM commands, and fault recovery.

Engine Cooling Controller - MATLAB Validation

Project structure

.github/workflows/ci.yml       GitHub Actions workflow
include/cooling_controller.h   Public types and controller API
src/cooling_controller.c       State machine, fault logic, HAL outputs
src/main.c                     PC thermal simulation and mock hardware
tests/test_cooling_controller.c C assertion-based unit tests
Makefile                        Build and test commands
.gitignore                      Generated files excluded from Git
LICENSE                         MIT license
README.md                       Project documentation

Build and run

Requirements: a C11-capable GCC compiler and GNU Make. No third-party C libraries or real hardware are required. The steps below were exercised on Windows using GCC and GNU Make through Git Bash.

From the project root:

make test   # Build and run the 10 unit tests
make sim    # Build and run the 20-step simulation
make clean  # Remove generated binaries and object files

Alternatively, compile the test executable directly:

gcc -std=c11 -Wall -Wextra -Werror -Iinclude \
  tests/test_cooling_controller.c src/cooling_controller.c -o cooling_tests
./cooling_tests

On Windows, the compiled executable can have an .exe suffix. The expected test summary is:

All cooling controller unit tests passed (10/10).

Automated tests

The project uses standard C assert() calls, with no external test framework.

ID Test function Behavior checked
R1 test_config_validation Valid configuration, invalid threshold ordering, null arguments
R2 test_normal_operation Normal OFF / LOW / HIGH transitions
R3 test_low_hysteresis LOW-stage hysteresis
R4 test_high_hysteresis HIGH-stage hysteresis
R5 test_direct_high_activation Direct OFF → HIGH transition
R6 test_sensor_failure Invalid sensor signal and HIGH fallback
R7 test_invalid_temperature Values outside the valid sensor range
R8 test_fault_recovery Three valid readings and recovery across temperature bands
R9 test_interrupted_recovery Recovery counter resets after a new invalid reading
R10 test_state_getters_and_hal State accessors and mock PWM/fault callbacks

The CI workflow runs the tests and simulation and performs Cppcheck static analysis on pushes to main and pull requests targeting main.

These tests check selected behaviors; they do not establish exhaustive coverage or functional-safety compliance.

Limitations

This is a PC-based educational simulation, not a production-ready ECU implementation.

  • No real temperature sensor, PWM peripheral, fan motor, or fault LED is connected.
  • HAL callbacks only demonstrate a possible hardware interface; no MCU driver is provided.
  • The thermal plant is simplified, with no calibrated physics or realistic sensor noise.
  • Calls to cooling_update() are simulated steps, not a real-time scheduler with timing guarantees.
  • No CAN communication, diagnostics protocol, or physical fan-failure monitoring is implemented.
  • The project does not implement or claim AUTOSAR or ISO 26262 compliance.