The application's stylesheet paints every read-only text edit in the window's grey, over the white base the Help window set in its palette: the pages were read at less contrast. A stylesheet on the browser itself wins. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…lagged Open calibration...: a calibration and its bead stacks part ways, and its results could not be seen again. A saved pupil model or bead average (one channel or two) now keeps, in a group of its own (calibrate/saved_run.py), the settings, where each stack was, the bead table, the averaged model against the data, the fit quality, and for the pupil model its bead map and start model. Opened, every page draws from the file alone; the stacks come back where they were, beside the calibration, or from a folder the user picks (Cancel: the file alone). uipsf's load_model reads a model from a named group, for the start. The assistant has it as a window action. Bead diameter: 0 stays the default (40 and 100 nm beads are both in use), but with beads its label is red while it is 0, the plugin's form says so, and a run warns. The plugin's form notice for an unknown method is a Notice now. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
What changed
Open calibration... (PSF calibration window). A calibration and its bead stacks part ways (copied elsewhere, stacks archived), and its results could then not be seen again. A saved run of the pupil model or the bead average, one channel or two, now keeps in its file a group of its own (
psf_window,calibrate/saved_run.py, a few hundred kB):psf_window_start);It is written after every save, Save as... and Uncertainty from halves..., and by the plugin's headless run. Opening a file sets sample, method, mode and settings, and draws every page from the file alone. The stacks go back into the file list where they are found: where they were, at the same place relative to the calibration, or (asked) by name and size in a folder the user picks. Cancel shows the file alone; if only some are found, none are added. With the stacks, Calibrate makes the calibration again. A file from before this change, or from another method, says that only its spline can be used.
uipsf.load_model(..., group=): reads a model from a named group, for the start model.gui/window_actions.py).Bead diameter of 0. 0 stays the default (40 and 100 nm beads are both in use), but it is rarely right. With beads, bead diameter's label is red while it is 0, the plugin's form shows a notice, and a run puts it in the warning line (
pupil.bead_size_warning). Also fixed: the plugin's form notice for an unknown method was a plain string, not aNotice.Help window. The app-wide stylesheet painted read-only text edits in the window's grey over the white base the Help window set, so pages were read at less contrast. A stylesheet on the browser itself fixes it.
For the reviewer
.h5does not route to the window yet.Tests
New
tests/test_saved_run.py: the tree round trip, finding moved stacks, a bead average opened from its file, the window's open with stacks, with Cancel and from a chosen folder, the bead-diameter flag. The long pupil-model test also opens its saved run and a start-model group.--slow -n 4: 4709 passed, 84 skipped--long:test_the_pupil_model_learns_from_the_beads_without_the_windowpassed (the only long test touched)🤖 Generated with Claude Code