# Changelog

## sungrow 1.6.0

Read the live values once a second. `driver_poll` returns 1000 ms. Each poll
reads grid, PV and battery power, SoC, per-phase values and the EMS readback.
Energy counters, rated power, temperature, frequency and fault bits keep the
five-second rate. Between those reads each blob carries their last values, but
only when its own power read succeeded this poll. FTW stores each emit whole,
and its energy ledger starts over whenever a counter drops out.

A host that ignores the returned interval still polls every five seconds, and
then every poll reads everything, as before. FTW honours the return from
srcfl/ftw#1616.

A read FTW refused while it waited to reconnect no longer counts toward
treating a register as absent. At one poll per second, a two-second wait would
otherwise mark a whole block absent after one dropped packet.

## Tests: no invented numbers

- `drivers/tests/lua_harness/no_invented_numbers.lua` runs a driver twice with different registers, config and clock, then makes every read fail and every Modbus reply short. A number the driver still emits that is equal in both runs and was not read is invented: 0 W, 0 A, 0 % SoC, 50 Hz. A failed read must leave the value nil, so the host sends null. Sourceful's driver registry runs the same file on every publish.
Expand Down
4 changes: 2 additions & 2 deletions SUPPORT_STATUS.md
Original file line number Diff line number Diff line change
Expand Up @@ -156,8 +156,8 @@ Catalog source is not proof that a target can install or run a driver.
| solis_string | 1.1.3 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| sonnen | 2.0.3 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| sonnen | 2.0.3 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| sungrow | 1.5.10 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| sungrow | 1.5.10 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| sungrow | 1.6.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| sungrow | 1.6.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| tesla_cloud | 0.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| tesla_cloud | 0.1.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| tesla_vehicle | 0.2.5 | ftw-core | not_assessed | — | not_recorded | not_assessed |
Expand Down
10 changes: 5 additions & 5 deletions devices.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -1749,7 +1749,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "sungrow"
version: "1.5.10"
version: "1.6.0"
ders: [battery, meter, pv]
control: true
firmware_versions: ""
Expand All @@ -1760,7 +1760,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "sungrow"
version: "1.5.10"
version: "1.6.0"
ders: [battery, meter, pv]
control: true
firmware_versions: ""
Expand All @@ -1771,7 +1771,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "sungrow"
version: "1.5.10"
version: "1.6.0"
ders: [battery, meter, pv]
control: true
firmware_versions: ""
Expand All @@ -1782,7 +1782,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "sungrow"
version: "1.5.10"
version: "1.6.0"
ders: [battery, meter, pv]
control: true
firmware_versions: ""
Expand All @@ -1793,7 +1793,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "sungrow"
version: "1.5.10"
version: "1.6.0"
ders: [battery, meter, pv]
control: true
firmware_versions: ""
Expand Down
209 changes: 136 additions & 73 deletions drivers/lua/sungrow.lua
Original file line number Diff line number Diff line change
Expand Up @@ -9,7 +9,7 @@ DRIVER = {
id = "sungrow",
name = "Sungrow SH Hybrid Inverter",
manufacturer = "Sungrow",
version = "1.5.10",
version = "1.6.0",
protocols = { "modbus" },
capabilities = { "meter", "pv", "battery", "pv-curtail" },
description = "Sungrow SH-series hybrid inverters with LFP battery, via Modbus TCP.",
Expand Down Expand Up @@ -224,11 +224,21 @@ end
local MISSES_BEFORE_SKIP = 3
local miss_counts = {}

-- FTW refuses a read without sending it while it waits to reconnect. That
-- proves nothing about the register, and a two-second wait spans two polls
-- at one per second: counting it would mark a whole block absent after one
-- dropped packet.
local function never_sent(ok, first, second)
local why = ok and second or first
return type(why) == "string" and why:find("reconnect backoff", 1, true) ~= nil
end

local function optional_read(address, count, kind)
if (miss_counts[address] or 0) >= MISSES_BEFORE_SKIP then
return nil
end
local ok, registers = pcall(host.modbus_read, address, count, kind)
local ok, registers, err = pcall(host.modbus_read, address, count, kind)
if never_sent(ok, registers, err) then return nil end
-- Check every register asked for, not just the first. A short reply leaves
-- the rest nil, and arithmetic on nil ends the whole poll.
if ok and registers ~= nil then
Expand Down Expand Up @@ -403,9 +413,34 @@ end

----------------------------------------------------------------------------
-- Telemetry polling
--
-- The live view moves once a second, so power, SoC, per-phase values and the
-- EMS readback are read on every poll. Energy counters, nameplate,
-- temperature, frequency and fault bits change slowly and keep their
-- five-second rate. Between those full reads each blob carries their last
-- values, so a counter never drops out of the energy ledger -- but only on a
-- poll whose own power read succeeded, so they never outlive the device.
--
-- A host that ignores the returned interval polls every five seconds, and
-- then every poll is a full read, as before.
----------------------------------------------------------------------------

local POLL_MS = 1000
local FULL_READ_MS = 5000
local last_full_read_ms = nil
local slow = {}

local function full_read_due(now_ms)
-- Half a poll early, so jitter cannot push each full read a second late.
return last_full_read_ms == nil
or now_ms - last_full_read_ms >= FULL_READ_MS - POLL_MS / 2
end

function driver_poll()
local now_ms = host.millis()
local full = full_read_due(now_ms)
if full then last_full_read_ms = now_ms end

-- driver_init already asked once. Keep asking while the answer is unknown,
-- up to DETECT_ATTEMPTS, then settle on probing.
if model_family == nil and detect_tries < DETECT_ATTEMPTS then
Expand Down Expand Up @@ -444,11 +479,14 @@ function driver_poll()
-- reachable-but-stopped inverter is no longer misreported as merely 0 W.
-- Hybrid only: an SG string inverter answers neither, and asking fails
-- the whole poll.
-- The running state is read on full polls only; the fault flag it sets
-- stays with the host until a later full poll clears it. The flow status
-- signs the battery power, so it is read with it on every poll.
local running_state = 0
local power_flow_status = 0
local running_state_known = false
if hybrid_block_worth_reading() then
local running_regs = optional_read(12999, 1, "input")
local running_regs = full and optional_read(12999, 1, "input")
if running_regs then
running_state = running_regs[1]
running_state_known = true
Expand Down Expand Up @@ -502,35 +540,42 @@ function driver_poll()
pv_source = "mppt_sum"
end

-- PV lifetime energy: 13002-13003, U32 LE × 0.1 kWh
-- Slow readings, on full polls only: lifetime energy, rated power,
-- heatsink temperature and grid frequency.
local pv_gen_wh = 0
if hybrid_block_worth_reading() then
local pvgen_regs = optional_read(13002, 2, "input")
if pvgen_regs then
pv_gen_wh = host.decode_u32_le(pvgen_regs[1], pvgen_regs[2]) * 0.1 * 1000
local rated_w = rated_ac_w
local heatsink_c = 0
local hz = 0
if full then
-- PV lifetime energy: 13002-13003, U32 LE × 0.1 kWh
if hybrid_block_worth_reading() then
local pvgen_regs = optional_read(13002, 2, "input")
if pvgen_regs then
pv_gen_wh = host.decode_u32_le(pvgen_regs[1], pvgen_regs[2]) * 0.1 * 1000
end
end
end

-- Rated power: 5000, U16 × 0.1 kW
local rated_regs = optional_read(5000, 1, "input")
local rated_w = rated_ac_w
if rated_regs then
rated_w = rated_regs[1] * 0.1 * 1000
if rated_w > 0 then rated_ac_w = rated_w end
end
-- Rated power: 5000, U16 × 0.1 kW
local rated_regs = optional_read(5000, 1, "input")
if rated_regs then
rated_w = rated_regs[1] * 0.1 * 1000
if rated_w > 0 then rated_ac_w = rated_w end
end

-- Heatsink temp: 5007, I16 × 0.1 C
local temp_regs = optional_read(5007, 1, "input")
local heatsink_c = 0
if temp_regs then
heatsink_c = host.decode_i16(temp_regs[1]) * 0.1
end
-- Heatsink temp: 5007, I16 × 0.1 C
local temp_regs = optional_read(5007, 1, "input")
if temp_regs then
heatsink_c = host.decode_i16(temp_regs[1]) * 0.1
end

-- Grid frequency: 5241, U16 × 0.01 Hz
local hz_regs = optional_read(5241, 1, "input")
local hz = 0
if hz_regs then
hz = hz_regs[1] * 0.01
-- Grid frequency: 5241, U16 × 0.01 Hz
local hz_regs = optional_read(5241, 1, "input")
if hz_regs then
hz = hz_regs[1] * 0.01
end
slow.pv_gen_wh, slow.heatsink_c, slow.hz = pv_gen_wh, heatsink_c, hz
elseif pv_regs or mppt_regs then
pv_gen_wh, heatsink_c = slow.pv_gen_wh, slow.heatsink_c
end

host.emit("pv", {
Expand All @@ -550,27 +595,29 @@ function driver_poll()
-- Diagnostics: long-format TS DB. Surface BOTH the primary-register
-- reading and the MPPT-derived fallback so operators can see when
-- the two disagree (= firmware register quirk) directly in the
-- metric browser.
host.emit_metric("pv_w_primary", pv_w_primary)
host.emit_metric("pv_w_mppt_sum", pv_w_mppt)
host.emit_metric("pv_raw_u32", pv_raw_u32)
host.emit_metric("pv_mppt1_v", mppt1_v)
host.emit_metric("pv_mppt1_a", mppt1_a)
host.emit_metric("pv_mppt1_w", mppt1_w)
host.emit_metric("pv_mppt2_v", mppt2_v)
host.emit_metric("pv_mppt2_a", mppt2_a)
host.emit_metric("pv_mppt2_w", mppt2_w)
host.emit_metric("inverter_temp_c", heatsink_c)
host.emit_metric("grid_hz", hz)
host.emit_metric("sungrow_running_state", running_state)
host.emit_metric("sungrow_power_flow_status", power_flow_status)
host.emit_metric("sungrow_pv_curtail_method", pv_curtail_method == "feed_in" and 2 or 1)
-- metric browser. Metrics keep the full-read rate.
if full then
host.emit_metric("pv_w_primary", pv_w_primary)
host.emit_metric("pv_w_mppt_sum", pv_w_mppt)
host.emit_metric("pv_raw_u32", pv_raw_u32)
host.emit_metric("pv_mppt1_v", mppt1_v)
host.emit_metric("pv_mppt1_a", mppt1_a)
host.emit_metric("pv_mppt1_w", mppt1_w)
host.emit_metric("pv_mppt2_v", mppt2_v)
host.emit_metric("pv_mppt2_a", mppt2_a)
host.emit_metric("pv_mppt2_w", mppt2_w)
host.emit_metric("inverter_temp_c", heatsink_c)
host.emit_metric("grid_hz", hz)
host.emit_metric("sungrow_running_state", running_state)
host.emit_metric("sungrow_power_flow_status", power_flow_status)
host.emit_metric("sungrow_pv_curtail_method", pv_curtail_method == "feed_in" and 2 or 1)
end

-- Contiguous bitfields from documented input registers 13050-13079
-- (zero-based host addresses 13049-13078). One read gives enough evidence
-- to distinguish thermal, grid, PV/DC, battery and BMS shutdowns.
local fault_regs = nil
if hybrid_block_worth_reading() then
if full and hybrid_block_worth_reading() then
fault_regs = optional_read(13049, 30, "input")
end
local fault_values = {}
Expand Down Expand Up @@ -650,7 +697,7 @@ function driver_poll()
if hybrid_block_worth_reading() then
emsd = optional_read(13049, 3, "holding")
end
if emsd then
if emsd and full then
host.emit_metric("sungrow_ems_mode", emsd[1]) -- 0=self, 2=forced, 3=ext
host.emit_metric("sungrow_force_cmd", emsd[2]) -- 0xAA=170 chg, 0xBB=187 dis, 0xCC=204 stop
host.emit_metric("sungrow_force_w", emsd[3])
Expand All @@ -673,21 +720,30 @@ function driver_poll()

-- Energy counters are separate reads. Add each only if it answered:
-- a counter reported as zero would look like a reset meter.
local bchg_regs = optional_read(13040, 2, "input")
if bchg_regs then
battery.charge_wh =
host.decode_u32_le(bchg_regs[1], bchg_regs[2]) * 0.1 * 1000
end
if full then
local bchg_regs = optional_read(13040, 2, "input")
if bchg_regs then
battery.charge_wh =
host.decode_u32_le(bchg_regs[1], bchg_regs[2]) * 0.1 * 1000
end

local bdis_regs = optional_read(13026, 2, "input")
if bdis_regs then
battery.discharge_wh =
host.decode_u32_le(bdis_regs[1], bdis_regs[2]) * 0.1 * 1000
local bdis_regs = optional_read(13026, 2, "input")
if bdis_regs then
battery.discharge_wh =
host.decode_u32_le(bdis_regs[1], bdis_regs[2]) * 0.1 * 1000
end
slow.charge_wh, slow.discharge_wh = battery.charge_wh, battery.discharge_wh
else
battery.charge_wh, battery.discharge_wh = slow.charge_wh, slow.discharge_wh
Comment on lines +736 to +737

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

P1 Badge Stop re-emitting cached slow values as fresh

Between full reads, this copies the previous battery counters into a new one-second host.emit without preserving their observation time or marking them stale; the analogous PV and meter caches do the same. Whenever live power continues but a slow field has not been reread, consumers therefore receive that old measurement as part of a fresh sample, contrary to the repository requirement not to emit stale cached telemetry as fresh. Keep the original sample age explicitly or avoid replaying these fields.

AGENTS.md reference: AGENTS.md:L71-L75

Useful? React with 👍 / 👎.

end

host.emit("battery", battery)
host.emit_metric("battery_dc_v", bat_v)
host.emit_metric("battery_dc_a", bat_a)
if full then
host.emit_metric("battery_dc_v", bat_v)
host.emit_metric("battery_dc_a", bat_a)
end
elseif full then
slow.charge_wh, slow.discharge_wh = nil, nil
end

-- Grid meter power: 5600-5601, I32 LE, watts (positive=import, negative=export)
Expand Down Expand Up @@ -729,15 +785,20 @@ function driver_poll()
-- rather than zeroed when absent: a counter reading zero looks like a
-- meter that was reset.
local import_wh, export_wh = nil, nil
if hybrid_block_worth_reading() then
local imp_regs = optional_read(13036, 2, "input")
if imp_regs then
import_wh = host.decode_u32_le(imp_regs[1], imp_regs[2]) * 0.1 * 1000
end
local exp_regs = optional_read(13045, 2, "input")
if exp_regs then
export_wh = host.decode_u32_le(exp_regs[1], exp_regs[2]) * 0.1 * 1000
if full then
if hybrid_block_worth_reading() then
local imp_regs = optional_read(13036, 2, "input")
if imp_regs then
import_wh = host.decode_u32_le(imp_regs[1], imp_regs[2]) * 0.1 * 1000
end
local exp_regs = optional_read(13045, 2, "input")
if exp_regs then
export_wh = host.decode_u32_le(exp_regs[1], exp_regs[2]) * 0.1 * 1000
end
end
slow.import_wh, slow.export_wh = import_wh, export_wh
elseif mw_regs then
import_wh, export_wh, hz = slow.import_wh, slow.export_wh, slow.hz
end

-- 5600-5601 relay the external meter on the known SH register map. Only an
Expand All @@ -763,15 +824,17 @@ function driver_poll()
import_wh = import_wh,
export_wh = export_wh,
})
host.emit_metric("meter_l1_w", l1_w)
host.emit_metric("meter_l2_w", l2_w)
host.emit_metric("meter_l3_w", l3_w)
host.emit_metric("meter_l1_v", l1_v)
host.emit_metric("meter_l2_v", l2_v)
host.emit_metric("meter_l3_v", l3_v)
host.emit_metric("meter_l1_a", l1_a)
host.emit_metric("meter_l2_a", l2_a)
host.emit_metric("meter_l3_a", l3_a)
if full then
host.emit_metric("meter_l1_w", l1_w)
host.emit_metric("meter_l2_w", l2_w)
host.emit_metric("meter_l3_w", l3_w)
host.emit_metric("meter_l1_v", l1_v)
host.emit_metric("meter_l2_v", l2_v)
host.emit_metric("meter_l3_v", l3_v)
host.emit_metric("meter_l1_a", l1_a)
host.emit_metric("meter_l2_a", l2_a)
host.emit_metric("meter_l3_a", l3_a)
end

-- Feed-in fallback translation: a PV allowance is the power that may
-- serve local load, charge the battery, or leave the site. Sungrow's
Expand All @@ -783,7 +846,7 @@ function driver_poll()
local load_w = meter_w - bat_w + pv_w
latest_non_export_w = math.max(0, load_w + math.max(0, bat_w))

return 5000
return POLL_MS
end

----------------------------------------------------------------------------
Expand Down
Loading
Loading