TCP Communication Protocol Layout

byte 0-7 byte 8-15 byte 16-X
com code com code data
signal code data length data

signal code:

The signal code specifies what kind of data is send. The signal code can contain the following numbers

  • 10: data contains acquisition meta data (data format: json)
  • 20: data contains frame header (data format: json)
  • 30: data contains frame (data format: int64)
  • 40: data contains acquisition end (data format: int64)

data length:

data length specifies the length of the data send in bytes

data:

data contains the data send in bytes