12 changes: 6 additions & 6 deletions Integrations/ESPHome/Core.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -325,7 +325,7 @@ sensor:
return isnan(offset) ? x : x + offset;
temperature:
id: dps310temperature
update_interval: 30s
update_interval: 60s
i2c_id: bus_a

- platform: sen5x
Expand Down Expand Up @@ -385,7 +385,7 @@ sensor:
# model option from esphome 2026.7.2.
model: sen55
address: 0x69
update_interval: 10s
update_interval: 60s

- platform: template
name: "PM 0.3 To 1 µm"
Expand All @@ -395,7 +395,7 @@ sensor:
unit_of_measurement: "µg/m³"
state_class: measurement
icon: mdi:air-filter
update_interval: 10s
update_interval: 60s

- platform: template
name: "PM 1 To 2.5 µm"
Expand All @@ -405,7 +405,7 @@ sensor:
unit_of_measurement: "µg/m³"
state_class: measurement
icon: mdi:air-filter
update_interval: 10s
update_interval: 60s

- platform: template
name: "PM 2.5 To 4 µm"
Expand All @@ -415,7 +415,7 @@ sensor:
unit_of_measurement: "µg/m³"
state_class: measurement
icon: mdi:air-filter
update_interval: 10s
update_interval: 60s

- platform: template
name: "PM 4 To 10 µm"
Expand All @@ -425,7 +425,7 @@ sensor:
unit_of_measurement: "µg/m³"
state_class: measurement
icon: mdi:air-filter
update_interval: 10s
update_interval: 60s

- platform: aqi
name: "NowCast AQI"
Expand Down
4 changes: 2 additions & 2 deletions Integrations/ESPHome/Predicted_Room.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -83,7 +83,7 @@ sensor:
device_class: temperature
state_class: measurement
accuracy_decimals: 2
update_interval: 10s
update_interval: 60s
lambda: |-
// Make sure the Air-1 is running at least for 3 minutes (avoid bad initial predictions).
// sys_uptime is NAN until its first publish, and NAN < 180.0 is false, so guard for it.
Expand Down Expand Up @@ -124,7 +124,7 @@ sensor:
device_class: humidity
state_class: measurement
accuracy_decimals: 1
update_interval: 10s
update_interval: 60s
lambda: |-
// Make sure the Air-1 is running at least for 3 minutes (avoid bad initial predictions).
// sys_uptime is NAN until its first publish, and NAN < 180.0 is false, so guard for it.
Expand Down